Testo 327 | Combustion analyser

Contact Instrument Solutions

The Testo 327-1 is an introductory instrument to flue gas analysis. It measures combustion efficiency, °C, O2, CO2, CO and flue draught. Supplied as standard with case, 180 mm long flue gas probe, power supply / battery recharger, or as an advanced kit with a thermal printer, hose & temperature set.

Features

The strong LED background light in the 4 line display guarantees an easy-to-read display even if lighting conditions are unfavourable. The analyser stands out on account of its easy menu navigation and ergonomic housing as well as its durability.

  • Easy menu navigation
  • 4 line segment display
  • LED display light
  • Easy IR printout
  • Built-in condensate trap
  • EN 50379 Part 2 for O2, °C, hPa
  • EN 50379 Part 3 for CO
  • Small Li-ion rechargeable battery (1200 mA, lifetime of > 5 h) can be recharged inside or outside instrument
  • Fast probe connection using single probe plug
  • Ambient CO measurement using flue gas probe
  • Separate AT temperature measurement
  • Draught measurement
  • Multiple fuel selection (Natural gas, propane, kerosene etc.)

Technical

Storage temperature      - 20 to + 50 °C

Operating temperature      - 5 to + 45 °C

Battery life      > 5 h

Weight      Approximately 500 g

Dimensions      216 mm x 68 mm x 47 mm

Probe type Type K:

Measuring range       - 40 to + 600 °C

Accuracy     ± 0.5 °C (0.0 to + 99.9 °C) ± 0.5 % of mv (100 to + 600 °C)

Resolution     0.1 °C

Draught measurement:

Measuring range       ± 40 hPa

Accuracy     ±0.02 hPa (-0.50 to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa)

Exhaust gas loss measurement:

Measuring range      0 to 99.9%

Resolution     0.1 %

Electrochemical measurement CO:

Measuring range     0 to 4000 ppm

Accuracy     ± 20 ppm (0 to 400 ppm) ± 5 % of mv (401 to 1000 ppm) ± 10 % of mv (1001 to 4000 ppm)

Electrochemical measurement O2:

Measuring range     0 to 21 Vol. %

Accuracy     ± 0.2 Vol. %

Resolution     0.1 Vol. %

Efficiency measurement (Eta):

Measuring range      0 to 120 %

Resolution     0.1 %

CO2 determination (calculation):

Measuring range     0 to CO2 max

Accuracy     ± 0.2 Vol. %

Reaction time      t90 Approximately 40 s

Support documents

  • Download
  • Category
  • File type
  • Download
Download
Testo 327 user manual.pdf Testo 327 user manual
Category
Technical document
File type
Adobe Acrobat
Download (1 MB)