Hontzsch flowtherm NT | ATEX vane anemometer hire kit

Contact BSRIA Instrumentation

Overview

The flowtherm NT a user-friendly handset fitted which is fitted with a 16 mm diameter aluminium 100 oC Ex category 3 (zone 2) rated vane probe which is suitable for a wide range of applications.

The instrument comes with datalogging capabilities that allows storage of up to 40,000 values with date and time as well as up to 100 different user profiles.

Features

  • Data logger for up to 40,000 values with date and time
  • USB interface for downloading the logged data to a PC
  • Analog output 0-10 V
  • Various measuring modes
  • Large, high-contrast display
  • Easy-to-use, tactile key feedback
  • Dynamic control keys
  • IP65 rated for use in hazardous areas ATEX category 3G (zone 2) areas

Technical

Type ZS16 vane head

Cylindrical vane wheel sensor / insertion probe with probe diameter 16 mm.

Measuring range 0.6 to 40.0 m/s

Probe material: aluminium.

Working temperature range from -20 to +100 °C.

Suitable for fixed measuring of actual flow velocity v [m/s] and flow rate V/t [m³/h, l/min] in clean gases.

ATEX Ex-protection category 3G (zone 2)

flowtherm NT handset

Display options:-

  • actual flow velocity [m/s], [ft/min]
  • actual flow rate [m³/h]
  • standard flow velocity [N-m/s]
  • standard flow rate [N-m³/h]
  • mass flow [kg/h]

Analog output 0 - 10 V (Cable provided with all rental units)

IP protection: IP65 (housing)

HLOG II software

The transferred data can be displayed numerically in a spreadsheet or as an interactive line chart. The information can also be saved as a XLS or CSV file as well as the charts exported as JPG file.



Support documents

  • Download
  • Category
  • File type
  • Download
Download
Hontzsch flowtherm NT data sheet.pdf Hontzsch flowtherm NT data sheet
Category
Technical document
File type
Adobe Acrobat
Download (407 KB)
Download
Hontzsch flowtherm NT handset user manual.pdf Hontzsch flowtherm NT handset user manual
Category
Technical document
File type
Adobe Acrobat
Download (1014 KB)
Download
Hontzsch HLOGII software user manual.pdf Hontzsch HLOGII software user manual
Category
Technical document
File type
Adobe Acrobat
Download (897 KB)
Download
Hontzsch ZS16 vane head data sheet.pdf Hontzsch ZS16 vane head data sheet
Category
Technical document
File type
Adobe Acrobat
Download (401 KB)

Common customer questions & answers

QQuestion What data logging options are available?
AAnswer The flowtherm NT handset can log instantaneous values / long term measuements using the automatic 'AUTO' function, or via the 'START' function which starts logging at a pre set time. Data can also be collected with a 'START-STOP' mode (timer).
QQuestion How long do the batteries last?
AAnswer This depends on the battery type, but typically x4 Duracell Plus type batteries will last for approximately 24 hours. If a long term monitoring exercise is to be conducted the instrument can be run via a USB plug in power supply but this not suitable for use in hazardous areas.