Close

Are you visiting bsria.com from outside your region? Visit your regional site for more relevant services and pricing.

Time Electronics 1044

Contact Instrument Solutions

Time Electronics voltage and current calibrator, case, test leads and calibration certificate

Overview

The Time Electronics 1044 is a precision handheld calibrator that can be used as a general purpose current and voltage source. High performance and simple operation make it suitable for test engineers, R&D, service, and calibration technicians. Offering both versatility and practicality the 1044 can source and measure voltage and current. The 0.05% accuracy is ideal for simulation and calibration in most engineering applications.

Features

  • Measure voltage and current
  • Source voltage and current
  • 0.05% accuracy
  • 0 to 20V in 3 ranges
  • 0 to 20mA in 3 ranges
  • Battery power 9V PP3
  • Portable with carry case

In the source mode, voltage up to 20V and current up to 20mA are generated in three ranges. When in current source mode the 1044 has a high 24V compliance voltage which is ideal for powering process loops. In the measurement mode, the range and function can be easily selected, with the measured input accurately shown on the LCD display.

The 1044 is housed in a pocket sized, ABS case and comes with a leatherette carry case containing a compartment for storing test leads. Connections are by standard 4mm plugs or by simply clamping the wires under the terminals. A single 9V battery powers the unit or an external 12V DC power supply may be used which disconnects the internal battery.

Technical

Applications

Common use of the 1044 is to simulate a transducer or measure the current flow in a transducer loop. The 1044 can be used to check a 4-20mA system in either source or measure mode, with the 24V compliance voltage powering the loop when current source mode is selected.

In the source mode, the 1044 may be used to calibrate meters, thermocouple indicators, data loggers, for signal injection, semiconductor characterisation, or as a backing off source. In the measure mode, the 1044 may be used in the same way as a DMM, checking DC voltages and current over 3 ranges with excellent resolution and accuracy.

Instrument accuracy

Please refer to the instrument user manual.

Support documents

  • Download
  • Category
  • File type
  • Download
Download
Time 1044 data sheet.pdf Time 1044 data sheet
Category
Technical document
File type
Adobe Acrobat
Download (157 KB)
Download
Time 1044 user manual.pdf Time 1044 user manual
Category
Technical document
File type
Adobe Acrobat
Download (374 KB)